Racewell

World Leader in Animal Management Technology

Automatic sheep drafting with the Superhandler Automatic cattle drafting in the Maxi Commander
Sheep/goat Rollover
Popular cattle headbail for the smaller cattle farmer
Home
Sheep Products
Cattle Products
Engineering
About Us
Contact Us
News & Events
Farming Scene
FAQ

Scales

Latest Newsletter
Links

Frequently Asked Questions

The table below provides a menu to problems that customers have experienced over time. We have included common problems with associated products not Racewell produced for your information

  1. Click on the menu option below to take you to this information
    Which compressor should I buy
    I dont have power at my work site
    Small backing gates not working
    Sheep unit not working but lights on in Board
    How do I disengage Backing hook
    Auto Entry gate doesn't open or opens too slowly or opens too fast
    Crush releases and catches straight away
    The remote doesnt work
    Pneumatics (air pressure is not working)
    The crush does not operate
    What size generator do I need to operate the system away from power

    The sheep crush is not wide enough

    The Racewell upgrade won't install to the Automation box
    Manual drafting doesn't work
    Iconix FX21 displays Nostore
    Iconix FX41 wont move off zero
    The crush wont release in FX21
    Iconix FX21 displays PPEE
    Iconix FX41 displays PGM Setup
    Iconix FX21 wont turn on or switches off

    Iconix FX41 not charging

    Unit Not drafting
    Unit not releasing with FX41
    Indicator not zeroing
    Indicator counting up or down when switched on
    Return Iconix FX41 to default settings
    The right draft gate stays across with Iconix FX21
    Life data and file data in Trutest XR300
    Unit not releasing with Trutest scales
    The difference between HDX and FDX electronic tags
  2. Which compressor should I buy

    Racewell units work with compressors that can provide up to 120psi. However rural power supplies are notoriously unstable and this needs to be taken into account which purchasing an adequate compressor. If you intend to do a lot of multi drafting on automatic then we recommend you consider buying a belt driven compressor These compressors require less power to start up and do not start up under load like the less expensive compressors.  Smaller compressors are designed to only have to start up around 8 times per hour.  More frequent demand results in the starter motor overheating and burning out.  If you are not using direct power – eg power is via a generator, then we recommend you purchase a “downloader compressor”.  This model keeps the motor running but does not compress air until it is required.  The result is the amps needed for the generator to start the compressor are significantly
    Reduced

    Back to top

    I don’t have power at my work site

    If you do not have power at your worksite this is not problem.  Air can be piped from a power source to the workplace by standard 12mm (1/2”) alkathene (polypipe).  The pipe acts as an additional reservoir.  As the compressor starts up on demand when the air pressure drops, having it away from the work site has the advantage of reducing the noise of the compressor where you are working

     

    Back to top

    Sheep unit not working but lights on in Board

    Cause:  Faulty 12 Adaptor

    Take top of  auto control box and check lights are on in board but wont go into test mode.

    Try using a 12 v battery in place of 12 v Adaptor

    Remedy:  Replace 12v adaptor

    Back to top

    Small Flapper Backing Gates do not Operate

    Cause:  These gates are gravity operated.  To work, they must be mounted on an angle that causes them to fall back once the sheep has passed through

    Remedy  Increase mounting angle so that gates open automatically

    Cause:  Sheep can still get back through the gates

    Remedy:  You race may be wider than standard and need to have the backing gates mounted on a packer to reduce the overall width where they are mounted

    Back to top

    How do I Disengage Backing hook

    Problem:  The pressure on the backing hook enables it to operate with the operation of the auto entry gate.  When you want to disengage this the pressure to the ram that activates the backing hook must be turned down.  This ram is on the off side of the unit directly behind where the backing hook comes through the side wall of the crush.

    Remedy:  On older units, turn pressure switch on backing hook ram in clockwise direction till auto backing hook does not move when sheep enter crush (Red Line)

    On newer units there is a black lever that automatically turns off the backing hook (green line)

    To re-engage  turn pressure switch in anti clockwise direction until backing hook is activated

    Back to top

    Auto Entry gate doesn't open or opens too slowly

    Cause:  Pressure on the ram valve is not enough

    Solution:  Turn brass pressure switch in  anti clockwise direction until desired speed is achieved

    Back to top

    Auto Entry gate shuts too fast or Violently

    Cause:  The pressure on the ram valve is too much

    Remedy:  Turn the brass pressure switch in an clockwise direction until the gate closes at the required speed

    Back to top

    Crush releases and catches straight away

    Probable cause 1: Dirt or wool on sensors

    Remedy: Clean sensors

    Probable cause 2: Sensor beam length too long

    Remedy: Contact Racewell for instructions

    Probable cause 3:  Faulty power source - AC Adaptor

    Try using a 12 volt battery source to see if the AC adaptor is faulty and needs repair or replace

    Also if unit is plugged in with extension cord, wires  in extension cord could be damaged. Try plugging another mains power appliance at the work site to check power from extension cord is OK

    Back to top

    Remote doesn’t work

    Problem:  Battery flat

    Remedy:  Replace internal battery

    Problem:  Remote not synchronised to crush

    Remedy:  Hold down catch button on remote for three seconds to synchronise to crush

    Back to top

    To Disengage Backing Hook on Sheep Superhandler

    The pressure on the backing hook enables it to operate with the operation of the auto entry gate.  When you want to disengage this the pressure to the ram that activates the backing hook must be turned down.  This ram is on the off side of the unit directly behind where the backing hook comes through the side wall of the crush.

    Remedy:  On older units, turn pressure switch on backing hook ram in clockwise direction till auto backing hook does not move when sheep enter crush (blue line) On newer units there is a black lever that automatically turns off the backing hook (blue line)

    To re-engage  turn pressure switch in anti clockwise direction until backing hook is activated

    Back to top

    Pneumatics (Air Pressure) not working

    Things to Check:

    No chewed or damaged air lines

    Power is on

    Back to top

    Crush does not operate

    Check  power is on and air is hooked up and compressor working.  Check eye leads are not damaged - disconnect and see if unit works without eyes. 

    Try operating with a 12 v battery to see if AC adaptor is faulty.

    Back to top

    What size generator will I need to operate the sheep system away from electric power

    Requires 5,7 KVA generator or greater

    Back to top

    Sheep crush is not wide enough

    Remedy:  On the off side at the bottom front there is a spring loaded bolt and a number of adjustment holes.  Move the wall across to an adjustment hole so that the crush is the desired width.  If desired the wall can be tapered with the adjustment holes making the crush a V shape.

    Also check that the push ram for the crush wall does not need adjustment.  Be sure that the wall will not close right away across as this could squash a hand.  To adjust the ram position, remove the R pin and position the ram in a more appropriate slot.  Reaffix the R pin

    Back to top

    Racewell upgrade wont install to automation box

    Cause:  Scale indicator is turned on

    Remedy:  Turn off scale indicator.  Retry down load process

    Back to top

    Manual drafting doesnt work

    Cause:  Autodraft is turned on at dashboard

    Remedy:  Turn autodraft switch  to off

    Back to top

    Iconix FX21 displays No store in indicator when trying to record weights

    Most common Cause: File selection is set on  Group 0.  This is a global (all files) setting

    Remedy:  Choose any other file from 1 to 100  that is appropriate - ie you might not want to record today's weights in the same file as a previous weighing

    Cause 2:  Has Racewell autobox programme prior to AD163 - version of file is written on side of autobox

    Remedy:  Requires upgrade to Racewell programme.  Log visit for upgrade to be carried out

    Cause 3:  Weighing process may be too fast for indicator to cope with

    Remedy:  Try slowing down sheep throughput into crush area

    Cause 4:  Load cell problem

    Remedy:  Contact Iconix 

    Back to top

    Iconix FX41 wont move off zero

    Cause:  Internal battery is flat

    Remedy: Recharge battery.  If it still wont move off zero indicator  it has lost span calibration send to Iconix.

    Back to top

    Crush wont release in Iconix FX21 system

    Problem:   Indicator memory is full and cannot process sheep in unit

    Solution:  Delete some records no longer required. 

    Back to top

    Iconix FX41 displays PGM Scale set up

    Cause:  Indicator battery flat

    Remedy:  Connect indicator to loadbars, turn on and press weigh key.  Check weights to see if recalibration is necessary. If this doesn't reset the indicator it will need to go to Iconix to have software re-installed

    NOTE:  Before weighing can commence the indicator must be charged even if you have successfully reset as above

    Back to top

    Iconix FX21 displays PPEE

    Cause:  Indicator battery flat

    Remedy:  Connect indicator to loadbars, turn on and press weigh key.  Check weights to see if recalibration is necessary. If this doesn't reset the indicator it will need to go to Iconix to have software re-installed

    NOTE:  Before weighing can commence the indicator must be charged even if you have successfully reset as above

    Back to top

    Iconix FX21 indicator wont turn on or switches off

    Cause:  battery flat

    Check:  Hold down on switch - if it stays on while on switch is held down it is flat battery

    Otherwise contact Iconix

    Back to top

    Iconix FX41 not charging

    Cause:  Indicator not turned on while charging

    Remedy:  FX41 must be switched on when charging

    Back to top

    Unit not drafting

    Possible cause flat battery or air line fault - can you hear air escaping anywhere?

    Back to top

    Unit is not auto releasing with Iconix FX41

    Possible Cause: If using FX41 battery low

    Remedy:  Ensure indicator is charged before commencing work

    Back to top

    Indicator not zeroing

    Problem:  moisture in connectors

    Remedy:  use hair dryer or similar to ensure connectors are dry.  Make sure protective plugs are in place between weighings

    Back to top

    Indicator counting up or down when switched on

    Cause 1:  Moisture in connectors

    Remedy: use hair dryer or similar to ensure connectors are dry.  Replace protection caps between weighings

    Cause 2:  Low battery

    Remedy:  Charge battery before commencing work

    Cause 3:  Electric fence interference

    Remedy:  Turn electric fence off to check if problem resolves.  Better earth on electric fenc required

    Cause 4:  Faulty indicator

    Remedy:  Send indicator to Iconix

    Back to top

    Return Iconix FX41 to Default Settings

    Setup Push "setup", "set up" (saved comes up) "50 ^PGMscale setup  Push Set up then weigh

    Back to top

    Right draft gate stays across with Iconix FX21

    Cause:  Drafter is turned off in setup of FX21

    Remedy:  Turn drafter back on in setup of FX21

    Back to top

    Life Data and File Data in the Trutest XR3000

    What are the differences between Life data and File data?

    Life data is the general data about an animal, such as date of birth, ID or breed that normally stays the same throughout the life of the animal.

    The life data for all animals is stored in a single database, called the Lifetime Animal Database (Life Data for short). Life data doesn’t need to be entered at each weighing session. Life data is entered once and then called up from the database when needed. File data is the data you collect during weighing sessions on an ongoing basis. For example, the animals weight, condition, and treatments given on a particular day.

    Up to 200 data files can be stored in the XR3000. Files can be identified by File Number, File Name, Date, Time, or a combination of these.

    Back to top

    Pasted from <http://www.trutest.co.nz/weighing_new/3000_faq.asp>

    Back to top

    Unit is not Auto releasing With Trutest Scales

    Cause:

    Remedy:  Turn unit on and off. 

    Check auto release switch on side of crush is on. 

    Check auto draft cable for damage

    Back to top

    What is the Difference Between HDX andDX Electronic eartags

    Both of these eartags are low frequency ear tags. This means they come within the range of what is internationally accepted for RFID. Half duplex tags transmit the electronic signal in only one direction at a time. Full duplex tags transmit the electronic signals in both directions. With RFID the tags are static or do not emit electronic signals until the tiny coil in the tag is excited by the RFID antennae (race reader/wand). Once excited it starts sending out its signal which is captured and interpreted by the reader head and presented as a legible number. This number is then often transmitted to the scales indicator or PDA to record liveweight data or select which group the animal belongs to for drafting.

     

     

    Sheep Products Cattle Products Engineering About Us
    Contact Us News & Events Farming Scene FAQ
    Scales Latest Newsletter Links Home

    Racewell Ltd - Te Kuiti - New Zealand - Ph + 64 7 8788977